Quick answer
Yes. Well-run CAD/CAM workflows routinely produce crowns with marginal gaps inside the roughly 120 µm limit long accepted as clinically acceptable. Accuracy depends on the whole chain: the scan or impression, the design settings, the milling machine and burs, and sintering.
What CAD/CAM means
CAD (computer-aided design): the crown is designed on a computer from a digital scan. CAM (computer-aided manufacturing): a milling machine or 3D printer makes it from that design. At Calvora we design in exocad and mill on 5-axis and 4-axis MEK machines in our Wakad lab.
How fit is measured
The marginal gap is the distance between the crown edge and the tooth's finish line. A classic study by McLean and von Fraunhofer (1971) proposed about 120 µm as the clinically acceptable limit, and that figure is still widely used. Studies of modern CAD/CAM crowns generally report mean marginal gaps comfortably below it.
Where accuracy is won or lost
| Step | What can go wrong | How to prevent it |
|---|---|---|
| Scan or impression | Missed margin, saliva, blood, distortion | Retraction, dry field, scan the margin clearly |
| Model | Trimming error, expansion | Digital model or careful die trimming |
| Design | Wrong cement gap, margin line in the wrong place | Correct spacer settings; technician checks the margin |
| Milling | Worn burs, tool too large for fine detail | Bur life tracking; 5-axis access to undercuts |
| Sintering | Distortion of long spans | Correct programme and support |
| Finishing | Over-grinding the margin | Adjust only where needed and re-polish |
4-axis vs 5-axis milling
A 5-axis mill can tilt the tool and the disc, so it reaches undercuts, deep fissures and angled implant screw channels that a 4-axis machine cannot. This matters most for implant work, long-span bridges and steep anterior anatomy. Calvora's MEK T8 Pro is a 5-axis mill with a 32-tool changer; see our technology page.
Digital impressions vs conventional
Intraoral scans are accurate for single crowns and short bridges, and they remove the risk of impression and stone errors. For full-arch implant cases, photogrammetry or a verified model improves accuracy further.
How to get better-fitting CAD/CAM crowns
- Make the finish line visible: retraction cord or paste, dry field.
- Scan or impress the adjacent teeth and opposing arch fully, plus a bite.
- Avoid feather-edge margins and sharp internal angles.
- Send clear notes: tight contacts, occlusal clearance, preferred cement gap.
- Ask your lab to tell you before milling if the margin is unclear.
Frequently asked questions
- Are CAD/CAM crowns as accurate as conventional crowns?
- Yes. Studies generally show CAD/CAM crowns with marginal fit equal to or better than conventional cast or pressed crowns, as long as the scan and design are good.
- What marginal gap is acceptable for a crown?
- About 120 µm is the widely used clinical limit, proposed by McLean and von Fraunhofer in 1971.
- Why does a CAD/CAM crown not seat?
- Usually an unclear margin in the scan, an undercut on the preparation, tight contacts, or a cement gap set too small.
References
- McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131(3):107-111.